Description

Main Unit, General-purpose Type, 28 Optical Axes
Model SL-C28L
Effective aperture angle Max. ±2.5 ° (when operating distance is at least 3 m)
Response time 15 ms *1
Light source Infrared LED (850 nm)
Operation mode Turned on when light is being applied to all optical axes (excluding when the blanking function is used)
Detection capability o45 mm*2
No. of beam axes 28
Detection zone 1080 mm
Protection area 1165 mm
Detectingdistance 0.3 to 9 m
Beam axis interval 40 mm
Lens diameter o5mm
OSSD output Output type 2 outputs each for PNP and NPN, Can be switched using the connection connector cable
Max. load current 300 mA *3
OFF-state voltage 2.5 V (with a cable length of 7 m)
Leakage current 100 µA maximum*4
Max. capacitive load 2.2 µF (with a load resistance of 100 ?)
Load wiring resistance 2.5 ? maximum*5
Approved standards EMC EMS UL61496-1
EMI FCC Part15 Class A
Safety UL61496-1 (type 4 ESPE), UL61496-2 (type 4 AOPD),UL508
Current consumption Transmitter 71 mA
Receiver 78 mA
Rating Power voltage 24 VDC ±10 %, Ripple (P-P) 10 % or less
Environmental resistance Enclosure rating IP65 (IEC60529)
Ambient light Incandescent lamp: 5,000 lux or less, Sunlight: 20,000 lux or less
Operating ambient temperature -10 to +55 °C (No freezing)
Storage temperature -10 to +60 °C (No condensation
Operating relative humidity 35 to 85 % RH (No condensation)
Storage relative humidity 35 to 95 % RH (No condensation)
Vibration resistance 10 to 55 Hz, Double amplitude 0.7 mm, 20 sweeps in each of the X, Y, and Z directions
Shock resistance 100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions
Weight Transmitter Approx 705 g
Receiver Approx 775 g
*1 OFF>ON return time is 125 ms. *2 If the SL-CL Series, which has a minimal detection object diameter of 45 mm, is used in conjunction with the SL-R12EX, the blanking function and muting function cannot be used. *3 Note the derating illustrated in the graph to the right when using PNP output. *4 This includes situations in which the SL-C Series is off and in which the power supply line is disconnected. *5 The wiring resistance between the OSSD output and the connected equipment (excluding the wiring resistance of the optional dedicated cable) must be 2.5 ? or less to ensure that the SL-C Series operate correctly. If using the NPN output
''