Description

Amplifier Unit
Model EX-510W
Type Controller
Shape M22, Threaded, Non-shielded
Measuring range 0 to 10 mm
Analogue output Output voltage 0 to 5 V (Output impedance: 100 ?)*1
Output current 4 to 20 mA (Applicable load: 0 to 350 ?)*1
Resolution 0.03% of F.S. (RESPONSE = 3,4)*1
Linearity ±0.3% of F.S. (RESPONSE = 2,3,4)*1
Response time (Response mode) 0.1 ms (RESPONSE = 1), 1 ms (RESPONSE = 2), 10 ms (RESPONSE = 3), 100 ms (RESPONSE = 4)*1
Disconnection alarm output (N.C.) NPN: 100 mA max. (40 V), Residual voltage: 1 V max.*2
Functions Auto-zero function/Auto-span function, Response time selector function/ Preset metal characteristic memory function, Cable length selector function/Interference suppression function
Temperature characteristics 0.04% of F.S./°C*1
Temperature fluctuation Sensor head 0.03 % of F.S./°C*3*4
Temperature characteristics Amplifier unit 0.04 % of F.S./°C*4
Rating Power voltage 12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less
Current consumption 220 mA max.
Environmental resistance Ambient temperature 0 to +50 °C (No freezing)
Relative humidity 35 to 85 % RH (No condensation)
Weight Approx. 360 g
*1 The above data was obtained using an aluminium target (A5052 t=1 mm). When measuring steel or stainless steel targets, refer to the characteristics of linearity for these materials. *2 NPN output can easily be converted to PNP output by connecting the optional OP-5148 PNP Output Converter. *3 When the distance between the sensor head and the target is 50 % of the measuring range and the operating temperature is 10 to +40 °C (EX-008) or 0 to +50 °C (EX-016 and EX-022). *4 The above data was obtained using an aluminum target (A5052 t = 1 mm). When measuring steel or stainless steel targets, refer to the characteristics of linearity for these materials.
''