Description

Sensor Head, without Monitor Function
Model LS-7070
Type Large-diameter
Classification without monitor camera
Measurement range 0.5 to 65 mm
Smallest detectable object 0.5 mm
Transmitter/receiver distance 250 ±50 mm
Repeatability ±0.2 µm*1
Measurement accuracy ±3 µm*2
Sampling cycle 2,400 samples/sec.*3
CCD scanning range Approx. 69 mm
Light source GaN green LED
Monitor camera Not provided
Environmental resistance Enclosure rating IP64*4
Ambient temperature 0 to +50 °C
Relative humidity 35 to 85 % RH (No condensation)
Weight Transmitter: Approx. 540 g Receiver: Approx. 730 g Base: Approx. 660 g
*1 The value of ±2? when the outer diameter of a rod 20 mm in diameter is measured at the centre of the measuring area while the number of averaging measurements is set to 512. *2 The error when a moving rod 20 mm in diameter is measured within the measuring area of 20 x 40 mm. *3 1,200 samples/sec. when the mutual interference prevention function is used. *4 The connector section is excluded.
''