Description

Fibre Amplifier, M8 Connector Type, NPN
Model FS-N15CN
Type 1 output type
Output NPN
Input/Output configuration M8 connector *1
Main unit/Expansion unit Main unit
Control output 1 output NPN open collector 24 V or less, maximum 100 mA or less, residual voltage 1 V or less
External input 1 input Input time 2 ms (ON)/20 ms (OFF) or more, when selecting External calibration 25 ms (ON/OFF) or more
Response time 50 µs (HIGH SPEED) /250 µs (FINE) /500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA)
Multiple connections to Expansion units 0 units (expansion not possible)
Output toggle LIGHT-ON/DARK-ON (switch-selectable)
Light source Red, 4-element LED (Wavelength: 630 nm)
Timer function Timer OFF/OFF-delay timer/ON-delay timer/One-shot timer
Protection circuit Reverse polarity protection, Over-current protection, Surge absorber
Number of interference prevention units 0 units (connection not possible)
Case dimensions H30.3mmxW9.8mmxL71.8mm
Rating Power voltage 12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less
Current Consumption Normal: 900 mW or less (36 mA max. at 24 V, 48 mA max. at 12 V) *2 Econ on (ALL): 800 mW or less (32 mA max. at 24 V, 39 mA max. at 12 V) *2 Eco full: 470 mW or less (19 mA max. at 24 V, 23 mA max. at 12 V)
Environmental resistance Enclosure rating IP66*3*4
Ambient light Incandescent lamp: 20,000 lux or less, Sunlight: 30,000 lux or less
Ambient temperature -20 to +55 °C (No freezing)
Relative humidity 35 to 85 % RH (No condensation)
Vibration resistance 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions
Shock resistance 500 m/s2, 3 times in each of the X, Y, and Z directions
Case material Main unit: glass-reinforced PBT, Cover: Sulfonic resin
Material Adapter Glass-reinforced PBT
Weight Approx. 30 g
*1 Use a cable of 30 m or less. *2 When the Power Mode is set to HIGH SPEED, 100 mW (4.0 mA) will be added. *3 About the enclosure rating when a small-diameter fibre unit (the diameter of the cable is o1.3 or o1.0) is used. IP66/IP65 cannot be satisfied when the type whose diameter is o1.3 and terminal can be separated (FU-4F/ 66/91/93/43/63/63T etc.) is used. When any small-diameter fibre units except for the above are used, IP65 is applied. *4 In any of the following cases, the enclosure rating IP66/IP65 cannot be satisfied. When the Fibre Unit and KEYENCE's M8 connector cable are not connected (Recommended conditions to tighten up the M8 connector: Tighten it by hand first.Then retighten it as much as 1/16-1/8 of a rotation with pliers.) When the Fibre Unit and KEYENCE's M8 connector cable are not connected When the dust cover of the Sensor Amplifier is open When there is debris in the dust cover When the waterproof adapter A/B are not used at the time of installation of a small-diameter fibre unit.
''