Headquater is in
the centre of Europe
Warranty is up
to 12 months
to 12 months
Best
prices
prices
Savings varies
from 15 to 55%
from 15 to 55%
Shipping
worldwide
worldwide
All shipments
are insured
are insured
Free
shipping
shipping
Our array of items consists of huge number of goods of the Keyence. Keyence produces dynamic and innovative products that always detect the resolution for the hard industrial concerns at any time. The Keyence achieves the high standards of equipment performance while creating the modern technologies that improve the work cycle of the industries. The Keyence Sensor Keyence LV-N11N is one of the masterly designed items. Keyence Sensor Keyence LV-N11N attributes extreme exactness, which offer wide range of automatic and electric resolutions to fulfill all application needs. Because of the high quality of constituents, Keyence Sensor Keyence LV-N11N ensure long time of use.
As the greatest industrial provider of various brands, we always devoted to establish brilliant experience to our consumers by offering huge number of industrial outfit and constituent parts at affordable prices with the brilliant chain of supply in the brief period of time. A top level of determination permit us to distribute any shape of product in the quickest period of time and respond the needs of our consumers in the processing sector. As for the price and delivery time, please fill in the form or submit your order to sales@famaga.us">sales@famaga.us
As the greatest industrial provider of various brands, we always devoted to establish brilliant experience to our consumers by offering huge number of industrial outfit and constituent parts at affordable prices with the brilliant chain of supply in the brief period of time. A top level of determination permit us to distribute any shape of product in the quickest period of time and respond the needs of our consumers in the processing sector. As for the price and delivery time, please fill in the form or submit your order to sales@famaga.us">sales@famaga.us
Description
Amplifier, Cable, Main unit, NPNModel | LV-N11N | |
Type | 2 output | |
Output | NPN | |
Cable/connector | Cable | |
Main/Expansion unit | Main unit | |
I/O | Control outputs | 2 output |
External input | 1 input | |
Monitor output | None | |
Response time | 80 µs (HIGH SPEED)/250 µs (FINE)/500 µs (TURBO)/1 ms (SUPER)/4 ms (ULTRA)/16 ms (MEGA) *1 | |
Output selection | LIGHT-ON/DARK-ON (switch-selectable) | |
Timer function | Timer OFF/OFF-delay timer/ON-delay timer/One-shot timer, Timer duration selectable: 1 ms to 9,999 ms, Maximum error against the setting value: ±10% max. | |
Control outputs | NPN open collector 30 V, Residual voltage 1 V or less (Output current: 10 mA or less) / 2 V or less (Output current: 10 to 100 mA) (Stand-alone) 1 output max: 100 mA or less, 2 output total: 100 mA or less (Multiple connections) 1 output max: 20 mA or less | |
Monitor output | - | |
External input | Input time 2 ms (ON)/20 ms (OFF) or more*2 | |
Multiple connections to expansion units | Up to 17 units can be connected in total (two-output type is treated as two units) | |
Protection circuit | Reverse polarity protection, Over-current protection, Surge absorber | |
Number of interference prevention units | Connected to other than LV-S31: 0 for HIGH SPEED, 2 for FINE/TURBO/SUPER, 4 for ULTRA/MEGA, Connected to LV-S31: 2 for FINE, 4 for TURBO/SUPER/ULTRA/MEGA*3 | |
Case size | H 32.6 mm ? W 9.8 mm ? L 78.7 mm | |
Rating | Power voltage | 24 VDC (operating voltage 10 to 30 VDC (with ripple)), Ripple (P-P) 10 % or less, Class 2 or LPS |
Power consumption | Normal: 830 mW or less (at 30 V. 30 mA at 24 V, 56 mA or less at 12 V)*4 Eco on mode: 710 mW or less (at 30 V. 26 mA at 24 V, 48 mA or less at 12 V)*4 Eco Full mode: 550 mW or less (at 30 V. 21 mA at 24 V, 40 mA or less at 12 V) *5 | |
Environmental resistance | Ambient temperature | -20 to +55 °C (No freezing)*6 |
Relative humidity | 35 to 85 % RH (No condensation) | |
Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions | |
Shock resistance | 500 m/s2, 3 times in each of the X, Y, and Z directions | |
Material | Cable | PVC |
Case | Main unit and cover material: Polycarbonate | |
Weight | Approx. 75 g | |
*1 80 µs cannot be selected when the LV-S31/S62/S63 is connected *2 Input time is 25 ms (ON)/25 ms (OFF) when external calibration time is selected. *3 These numbers double when 'DOUBLE' is selected. *4 Increases 30 mW (1 mA) for High Speed mode. *5 It increases by 15% when connected to the LV-NH100/NH110/NH300. It does not include the power consumption of the load. Power consumption when expansion units are connected is the total power consumption of each amplifier unit. Example: When one main unit (LV-N11N) is connected to 2 expansion units (LV-N12N) and they are used with LV-NH100 heads in HIGH SPEED mode. (1.15 ? 860 mW ? 1) + (1.15 ? 860 mW ? 2) = 2967 mW max. *6 If more than one unit is used together, the ambient temperature varies with the conditions below. Mount the units on the DIN rail with mounting brackets and check that the output current is 20 mA or less for a unit. One or two more units connected: -20 °C to +55 °C , 3 to 10 more units connected: -20 °C to +50 °C, 11 to 16 more units connected: -20 °C to +45 °C. When using 2-outputs, one unit is counted as two units. |