Description

Blower Type Main Unit
Model SJ-F5010
Type 600 mm type
Voltage application method Pulse AC method
Applied voltage ±7000V
Ion balance control method I.C.C.
Ion balance ±5 V*1
Static elimination time Approx. 1 sec*2
Operating distance 50 mm min.
Maximum wind speed 3.5 m/s*1
Maximum air volume 6.2 m3/min
Ozone density 0.005 ppm max.
Power source input type Terminal block DC input
Control input Static elimination stop input 24 VDC input
Control output Alarm/ Ion level alert/ Condition alert NPN open-collector 100 mA (40 V max.)
PNP open-collector 100 mA (24 V ±10%)
Rating Power voltage 24 VDC ±10 %
Current consumption 1.9 A
Environmental resistance Pollution degree 2
Overvoltage category II
Ambient temperature 0 to +50 °C
Relative humidity 35 to 65 % RH
Weight Approx. 4 kg
*1 Measured at a distance of 300 mm from the front of the fan *2 Measured at a distance of 300 mm from the front of the fan and at maximum air volume
''